Loading
Back to
View All
  • Products
    • ALL PRODUCTS
      • Contactors
      • Overload Protection
      • Starters + Enclosed Product
      • Motor Controllers + MCCBs
      • Softstarters
      • Circuit Protection
      • Disconnect Switches
      • Rotary Cam Switches
      • Control + Timing Relays
      • Pilot Devices
      • Signaling Devices
      • Terminals
      • Power Supplies
    • Custom Control Panels
      • Capabilities
      • Combination Starters
      • Explosion Proof
      • Multi-Speed and Reduced Voltage
  • Library
    • LIBRARY
      • Product Catalog
      • Literature
      • Cross Reference
      • Technical Tips & FAQs
      • CAD Drawings
      • Wiring Diagrams
    • APPROVALS
      • UL/CSA Documents
      • CE-DOC
      • Atex
      • CCC
      • RCM/TUV/ABS/RINA
      • ISO9001
      • SUVA Certificates
      • Functional Safety Data
      • Environmental Compliance
    • Training
      • SSU
  • Company
    • COMPANY
      • About Sprecher + Schuh
      • Contact Us
      • Industries Served
      • Success Stories
      • Terms & Conditions
      • Privacy Policy
      • Technical Support
      • International
  • Sales
    • SALES
      • Find a Reseller or Sales Rep
      • Become a Distributor
      • B2B Portal
    • CONTACT US
      • United States
      • Canada
      • International
  • Support
    • SUPPORT
      • Technical Support
      • Technical Tips & FAQs
      • Find a Reseller or Sales Rep
      • Contact Us
      • B2B Portal
      • SSU
Categories
    • Circuit Protection
    • Circuit Protection
    • Contactors
    • Contactors
    • Control Relays & Timers
    • Control Relays & Timers
    • Disconnect Switches
    • Disconnect Switches
    • Electrical Industry Codes
    • Electrical Industry Codes
    • Motor Controllers & MCCBs
    • Motor Controllers & MCCBs
    • Overload Protection
    • Overload Protection
    • Pilot Devices
    • Pilot Devices
    • Power Supplies
    • Power Supplies
    • Rotary Cam Switches
    • Rotary Cam Switches
    • Signaling Solutions
    • Signaling Solutions
    • Softstarters
    • Softstarters
    • Starters & Enclosed Products
    • Starters & Enclosed Products
    • Terminal Blocks
    • Terminal Blocks
  • Product 1
  • Product 2
  • Product 3
  • Product 4
 


How To Choose The Right KT7 Busbar Power Wiring System

 
 
 
 

Question:
There are several different types of bus bar systems available. How do I know which system to choose for my assembly? If I have an old bus bar system, what is the current replacement recommendation? What if I need to add a unit to an existing system?

Common Applications

The most common application of compact bus bar is in a multiple motor starter control panel. A multi-motor control panel could utilize a series of KTA7 or KTC7 motor controllers, either alone or with a contactor to make a Type E/F starter (CL7/CK7). Compact busbars allow power wiring of multiple units without running individual wires to each controller. The KTA7 or KTC7 would be used to protect motor loads, while KTU7 would be used to protect non-motor loads (transformer or heater).

Busbar Replacement On An Existing Assembly

When the panel assembly is using KTA7 or KTC7 exclusively, the KT7-32-DB busbars should be used. In 2011, Sprecher & Schuh discontinued the old "fork" stab KT7-25-DB in favor of the molded single stab KT7-32-DB models. For an older existing panel that needs a busbar replacement, the KT7-32-DB and KT7-25-DB cannot be mixed on the same power run as the connections are not satisfactory. All of the old KT7-25-DB on the same assembly run should be replaced with the KT7-32-DB of the same size for the best replacement fit.

 

Sprecher & Schuh Series KT7-32-54 Busbar
Sprecher & Schuh Series KT7-25-54 Busbar

Mixed Applications

In mixed applications, when KTA7 or KTC7 and KTU7 are being used in the same run, the KTU7-D-DB compact bus bar can be used to connect both the KTA7 and KTU7. This is possible because the KTU7 busbars have a built-in creepage distance of 2" as required by UL. KT7-32-DB compact bus bar will not work with KTU7, but KTU7-D-DB works well with both KTA7 and KTU7.

Sprecher & Schuh Series KTU7 molded case circuit breakers mounted on KTU7-D-DB busbar

If availability of replacement compact bus bar is an issue, then there are other alternatives to consider.

  • If the total connected load (current of a group) is not more than 30 Amps, the devices may be daisy-chain wired since the line terminals are #10 AWG (good for 30 amps).
  • If there are several KTA7 and only one or two KTU7 then you might consider using a second KT7-32-A3E supply block attached to the KT7 compact busbar to feed just the KTU7 from the compact busbar via wire.
  • If the above suggestions do not apply to the specific application, and KT7-32-DB is NOT an option, then you must consider using a power distribution block.

Older existing panel system that need to be updated to replacement motor control units or to meet a new UL requirement should be analyzed for replacement options and/or engineered cost savings.

For additional information please contact your nearest authorized distributor, sales representative, or call our customer service or technical support lines.

Sprecher & Schuh Series KF7 Fuse holders

Related Links

Methods of Applying KT Motor Controllers [PDF]